Railway Lighting Systems
Professional Lighting Solutions for European Rolling Stock
Product Overview
We specialize in the R&D and manufacturing of dedicated lighting systems tailored for European rail vehicles. Our comprehensive product portfolio covers high-speed EMUs, regional commuter trains, urban metros and light rail systems, delivering fully integrated solutions encompassing normal ambient lighting, emergency evacuation lighting, driver cab lighting and local task auxiliary lighting.
All products are engineered and manufactured in strict adherence to mandatory EU railway standards, catering to both new rolling stock assembly and retrofit renovation projects for railway operators across Europe.
Compliance Framework
EN 50121-3-2: Electromagnetic Compatibility for Railway Applications
|
Technical Requirement |
Design Implementation |
Validation Standard |
|
Controlled Conducted & Radiated Emissions |
Optimized PCB shielding, common-mode filtering and isolated grounding architecture |
Zero interference with on-board CAN bus, ATP safety systems and GSM-R communication equipment |
|
Full-Spectrum Interference Immunity |
Complete test coverage for ESD, RF radiation, electrical fast transients and surge pulses |
Achieves Class B EMC certification for railway onboard devices |
|
Transient Voltage Endurance |
Specialized circuit protection against brake voltage spikes and pantograph arc disturbances |
Stable, flicker-free luminous output with no abnormal flash alarms during transient surges |
EN 50155: Electronic Equipment Used on Rolling Stock
This standard sets the mandatory certification baseline for all onboard electronic assemblies, with all our lighting control modules fully compliant:
- Power Compatibility: Supports mainstream on-board DC supplies of 24V / 48V / 72V / 110V; withstands 70%~125% nominal voltage fluctuations and maintains full illumination during 10ms instantaneous power outages
- Environmental Resilience: Operates reliably across -30°C to +70°C; validated through high-temperature aging and low-temperature cold-start testing
- Mechanical Robustness: Passes 5–150Hz random vibration and mechanical shock benchmarks, eliminating risks of light source detachment, housing cracking or driver circuit failure over long-term operation
- Multi-Layer Circuit Protection: Constant-current driver circuits integrate overvoltage, overcurrent, short-circuit and thermal lockout safeguards, engineered for 24/7 uninterrupted train service
EN 13272 Series: Performance Specifications for Rolling Stock Interior Lighting
|
Standard Reference |
Applicable Vehicle Type |
Core Performance Criteria |
|
EN 13272-1 |
Mainline & High-Speed Trains |
Passenger saloon illuminance: 100–150lx, CRI Ra ≥ 80, Unified Glare Rating UGR ≤ 19 |
|
EN 13272-2 |
Urban Metro & Light Rail Transit |
Minimum corridor illuminance ≥ 75lx, light uniformity ≥ 0.7, zero dark blind zones |
Mandatory Emergency Lighting Performance Benchmarks:
Minimum 3-hour continuous backup runtime; evacuation route illuminance ≥ 50lx, critical operational zones ≥ 100lx
Supplementary Safety Standards
|
Standard Reference |
Core Mandate |
Compliance Specifications |
|
EN 45545 |
Railway Vehicle Fire Safety |
Luminaire housings, wiring and potting compounds meet HL2/HL3 flame-retardant grades with low smoke density and low toxic fume emissions |
|
IEC 60598 |
General Safety Requirements for Luminaires |
Minimum IP54 dust and water ingress protection; structural safeguards against electric shock and overheating hazards |
Dual-Tier System Architecture
Normal Lighting System (Primary Main Illumination)
Core Function: Delivers consistent baseline illumination for passenger saloons, driver cabs, connecting gangways and passenger boarding vestibules
Power Distribution: Zoned centralized power supply controlled via the vehicle’s main switchboard
|
Product Category |
Typical Installation Scenarios |
Key Technical Features |
|
General Ceiling Luminaires |
Primary ambient lighting for passenger compartments |
Stepless dimming capability, homogeneous light distribution, flicker-free operation |
|
Local Auxiliary Lights |
Passenger bedside reading lamps, vanity mirror fixtures |
Adjustable directional beam optics, switchable CCT ranging from 3000K to 6500K |
|
High-Intensity Floodlights |
Cargo wagons, maintenance bays and equipment storage rooms |
High luminous flux output, wide beam angles, dust and contamination-resistant surface treatment |
|
Continuous Corridor Lighting |
Passageways, inter-car gangways and stairwells |
Linear continuous layout with built-in linkage compatibility for emergency lighting activation |
Integrated Intelligent Control Functions
- Supports zone-based manual and automatic brightness dimming
- Programmable linkage with train operational modes: Day Mode, Night Mode and Tunnel Compensation Mode
- Independent wiring harnesses for each zone distribution panel to contain fault propagation and prevent cascading power failures
Emergency Lighting System (Backup Safety Illumination)
Core Function: Dedicated isolated power circuits with automatic 5-second switchover upon main power loss, fully aligned with EU passenger evacuation safety regulations
Activation Triggers
- ⚠️ Main traction generator shutdown fault
- ⚠️ Complete voltage depletion on the lighting busbar
- ⚠️ Interlock signal input from the fire alarm control panel
- ⚠️ Manual forced activation via the driver’s cab control console
Covered Zones & Performance Parameters
|
Zone Classification |
Minimum Illuminance |
Backup Runtime |
Structural Configuration |
|
Driver Cab & Central Equipment Rooms |
100lx |
≥ 3 hours |
Dual redundant power input design |
|
Escape Corridors & Emergency Exit Points |
50lx |
≥ 3 hours |
Integrated photoluminescent evacuation signage |
|
Passenger Assembly & Lifesaving Boarding Areas |
50lx |
≥ 3 hours |
Independent self-contained backup battery per luminaire unit |
Isolation Safety Design
Normal and emergency lighting circuits feature full electrical segregation with dedicated, separated cable tray routing. This design eliminates single-point failure risks that could result in full-vehicle blackout events.
R&D & Quality Assurance Framework
Standard-Driven Product Development
- Full cross-referencing against the complete suite of EN railway standards from the earliest R&D prototype phase
- End-to-end compliant design covering light source selection, driver circuit layout, mechanical housing construction and wiring insulation materials
- Synchronized hardware and firmware iterative upgrades aligned with the latest revisions of EU railway regulatory standards
Comprehensive Reliability Validation Testing
|
Test Category |
Test Scope |
Implementation Frequency |
|
Optical Performance Testing |
Illuminance, light uniformity, color rendering index and glare control |
Batch sampling inspection prior to shipment |
|
EMC Electromagnetic Compatibility Testing |
Conducted/radiated emissions and full anti-interference immunity |
Type approval testing for new models + annual recertification audits |
|
Environmental Endurance Testing |
Thermal cycling, damp heat aging and salt spray corrosion resistance |
Mandatory certification testing for all new product variants |
|
Mechanical Durability Testing |
Random vibration, mechanical shock and drop impact resistance |
Mandatory certification testing for all new product variants |
|
Fire Safety Performance Testing |
EN 45545 HL2/HL3 flame retardant characteristic verification |
Mandatory certification testing for all new product variants |
|
Emergency Backup Endurance Testing |
3-hour full-load discharge aging cycle |
Monthly random sampling spot checks |
Customization Capabilities
- Adjustable illuminance output, correlated color temperature and dimming logic tailored to individual railway operator specifications
- Custom mounting dimensions and vehicle-specific connector interfaces compatible with high-speed, regional and metro rolling stock
- Lightweight retrofit replacement luminaires for legacy fleets, requiring no modifications to the original vehicle wiring harness
Core Competitive Advantages
|
Advantage |
Delivered Customer Value |
|
✅ Full End-to-End Regulatory Compliance |
Fully conforms to EN 50121-3-2, EN 50155, EN 13272 and EN 45545; complete third-party test reports provided to support full vehicle CE certification submissions |
|
✅ Superior Harsh Environment Compatibility |
Wide operating temperature range, robust anti-vibration and anti-EMI performance, suitable for European alpine cold routes, high-temperature southern lines and long tunnel sections |
|
✅ Dual Redundant Safety Architecture |
Turnkey integrated normal + emergency lighting solution with zone-based intelligent control, balancing passenger visual comfort and critical operational safety |
|
✅ Continuous Performance Iteration |
Regular design optimizations informed by EU standard updates and real-world field operation feedback, reducing long-term vehicle lifecycle maintenance costs |
|
✅ One-Stop Holistic Lighting Portfolio |
Full coverage of interior, exterior, cab and evacuation lighting products, compatible with both new vehicle manufacturing and in-service fleet retrofit projects |
Application Scenarios
|
Vehicle Category |
Representative Project Types |
Matching Lighting Configuration |
|
High-Speed EMUs |
Cross-border European intercity expresses, long-distance high-speed rolling stock |
Main passenger saloon ambient lighting + individual reading lamps + full integrated emergency evacuation lighting system |
|
Regional Commuter Trains |
Suburban rail lines, short-distance regional passenger services |
Heavy-duty general ambient lighting + continuous linear corridor lighting |
|
Urban Metro Transit |
High-capacity underground metros, rapid light rail transit systems |
Dense linear luminaire layout + automatic adaptive intelligent dimming systems |
|
Urban Low-Floor Trams |
Ground-level city tram vehicles |
Slim, compact luminaires engineered for minimal routine maintenance |
|
Mainline Locomotive Cabs |
Electric and diesel freight/passenger locomotives |
High-output console task lighting + auxiliary instrument backlighting |
|
Specialized Rail Vehicles |
Track maintenance wagons, freight cargo carriages |